Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: Keystone Place
Address: 6126 Rockwell Dr NE
Cedar Rapids, IA  52402
Person Contacted: Unknown
Title: N/A
Registration No: SP57-104-100 \ SP57-104-101
Type: Routine

Water Quality Information
Name: Indoor Pool < 1500 sq ft Indoor Spa
Registration No: SP57-104-100 SP57-104-101
Area (Sq. ft.): 450 48
Volume (Gallons): 12350 900
Filter Type: Sand Sand
Filter Rate: - -
Turnover Rate: - -
Chlorine (Free): 3.6 3.8
ORP: 7.5/757/87 7.5/786
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total): 3.8 4.0
Chlorine (Combined): 0.2 0.2
Bromine: - -
Pool: 2-18ppm Spa: 4-18ppm
Cyanuric Acid: NA NA
Must be less than 80 ppm
pH: 7.2 7.4
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 80 50
Calcium Hardness: 190 240

 

Water Quality Information (continued)
Name: Indoor Pool < 1500 sq ft Indoor Spa
Registration No: SP57-104-100 SP57-104-101
Temperature (F): 87 103
Spa must not exceed 104°
Type of Disinfectant: Cal Hypo briquettes Cal Hypo briquettes
Disinfection make and model: Pulsar Precision 30 Pulsar Precision 30
Drain Cover make and model: Aquastar Aquastar
Drain Cover exp. date: 7-7-27 7-7-27
CPO: Mackenzie Phillips Mackenzie Phillips
CPO exp. date: 11-30-29 11-30-29

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: Routine pool inspection
-Reminder: Main drain covers expire in July '27.

Please email a letter of correction stating how the violations listed below have been and/or will be corrected to James.Aamodt@linncountyiowa.gov within 30 days of this inspection.

# Section Reference Ref. Page
1) Management/Personnel Pool: 15.4(6)f(4) 24
Spa: 15.51(5)e(5) 17
  Item: Dates and quantities of chemical additions must be included in Operational Records
  Comment: Please document this in your pool log.
   
2) Management/Personnel Pool: 15.4(6)f(6) 24
Spa: 15:51(5)e(8) 17
  Item: Monthly ground fault circuit interrupter (GFCI) testing shall be included in pool logs
  Comment: Please record this in your pool log.
   
3) Management/Personnel Pool: 15.4(6)f(5) 24
Spa: 15.51(5)e(6) 17
  Item: Dates when filters are backwashed, cleaned, or changed included in Operational Records
  Comment: Please record this in your pool log.
   
4) Management/Personnel Pool: 15.4(2)e 8
  Item: The swimming pool and/or spa water shall be tested for total alkalinity at least once in each week that they are open for use. The swimming pool and/or spa shall be tested for calcium hardness, total chlorine and cyanuric acid (outdoor pools only) at least once in each month that they are open for use
  Comment: Please ensure the monthly tests are being done and documented on your pool log.
   
5) Safety Spa: 15.51(4)l 16
  Item: The agitation system control (timer) shall be installed out of the reach of persons in the spa. The "on" cycle for the agitation system shall be no more than ten minutes
  Comment: The timer for the spa doesn't count down after it's turned on. Please fix or replace.
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).