| Swimming Pool / Spa Inspection Report Linn County Public Health 1020 - 6th Street SE Cedar Rapids, IA 52401 Phone: (319) 892-6000 Fax: (319) 892-6099 E-mail: health@linncountyiowa.gov |
Facility Name: Country Inn and Suites
Title: GM Registration No: SP57-061-100 \ SP57-061-101 Type: Routine |
| Name: | Indoor Pool < 1500 sq ft | Indoor Spa |
|---|---|---|
| Registration No: | SP57-061-100 | SP57-061-101 |
| Area (Sq. ft.): | 288 | 56 |
| Volume (Gallons): | 10000 | 800 |
| Filter Type: | Sand | |
| Filter Rate: | - | |
| Turnover Rate: | - | |
| Chlorine (Free): | 4.4 | |
| ORP: | 713/7.4 | |
| Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
||
| Chlorine (Total): | 4.8 | |
| Chlorine (Combined): | 0.4 | |
| Bromine: | - | |
| Pool: 2-18ppm Spa: 4-18ppm | ||
| Cyanuric Acid: | NA | |
| Must be less than 80 ppm | ||
| pH: | 7.2 | |
| Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
||
| Total Alkalinity: | 40 | |
| Calcium Hardness: | 230 | |
| Name: | Indoor Pool < 1500 sq ft | Indoor Spa |
|---|---|---|
| Registration No: | SP57-061-100 | SP57-061-101 |
| Temperature (F): | 82 | |
| Spa must not exceed 104° | ||
| Type of Disinfectant: | Cal Hypo | |
| Disinfection make and model: | Ecolab N-290 | |
| Drain Cover make and model: | Aquastar A10 round | |
| Drain Cover exp. date: | 6-1-28 | |
| CPO: | Penny Scovill-Wise | |
| CPO exp. date: | 11-30-29 | |
| 1. Facility in compliance with smoking ban? | |
| ( If no, complete complaint form ) | |
Notes: Routine pool inspection
-pool log occasionally had missing info, but overall looked good
Please email a letter of correction stating how the violations listed below have been and/or will be corrected to james.aamodt@linncountyiowa.gov within 30 days of this inspection.
| # | Section | Reference | Ref. Page | |
|---|---|---|---|---|
| 1) | Management/Personnel | Pool: | 15.4(6)f(6) | 24 |
| Spa: | 15:51(5)e(8) | 17 | ||
| Item: Monthly ground fault circuit interrupter (GFCI) testing shall be included in pool logs | ||||
| Comment: Please ensure GFCI testing is done each month and documented in the pool log. | ||||
| 2) | Management/Personnel | Pool: | 15.4(6)f(5) | 24 |
| Spa: | 15.51(5)e(6) | 17 | ||
| Item: Dates when filters are backwashed, cleaned, or changed included in Operational Records | ||||
| Comment: Please document the dates you backwash in the pool log. | ||||
| 3) | Safety | Pool: | 15.4(4)b(3) | 13 |
| Item: The lower end of each ladder rail shall be securely covered with a smooth nonmetallic cap. | ||||
| Comment: Please replace endcaps on bottom of ladder. | ||||
| 4) | Safety | Pool: | 15.4(6)k | 25 |
| Spa: | 15.51(5)i | 18 | ||
| Item: Each member of staff shall sign off that they have reviewed SDS sheets along with the Emergency Action Plan annually. | ||||
| Comment: Unable to locate current sheet at time of inspection. Please have staff review and sign off for SDS and EAP. | ||||
| Name | Date | ||
|---|---|---|---|
| Inspector: | Inspection: | ||
| Report Received By: | Received: | ||
| Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).