Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: YMCA Camp Wapsie
Address: 2174 Wapsie Y Rd
Coggon, IA  52218
Person Contacted: John Wick
Title: Caretaker
Registration No: SP57-025-100
Type: Routine

Water Quality Information
Name: Outdoor Pool >= 1500 sq ft
Registration No: SP57-025-100
Area (Sq. ft.): 3150
Volume (Gallons): 119500
Filter Type: Sand
Filter Rate: -
Turnover Rate: -
Chlorine (Free): 7.6
ORP: 735
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total): 8.0
Chlorine (Combined): 0.4
Bromine: -
Pool: 2-18ppm Spa: 4-18ppm
Water Quality Information (continued)
Cyanuric Acid: >30
Must be less than 80 ppm
pH: 7.6
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 140
Calcium Hardness: 200
Temperature (F): 78
Spa must not exceed 104°
Type of Disinfectant: Liquid Chlorine
Disinfection make and model: Becsys3
Drain Cover make and model: Hayward
Drain Cover exp. date: May, 2031
CPO: John Wick
CPO exp. date: 3-31-28

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: Routine pool inspection.

- please address gap in fence
- please fill hole/chip in the deck
- please ensure the SVRS is functioning properly and ready to go prior to opening for the 2027 season
Please email a letter of correction stating how the violations listed below have been and/or will be corrected to James.Aamodt@linncountyiowa.gov within 30 days of this inspection.

# Section Reference Ref. Page
1) Decks Pool: 15.4(4)k(1) 21
Spa: 15.51(4)h(1) 15
  Item: Pool and Spa decks shall be maintained slip-resistant, and free of litter, obstructions and tripping hazards.
  Comment: Please fill the hole where a piece of the deck has chipped away near one of the corners on the east side of the pool.
   
2) Safety Pool: 15.4(4)l(2) 21
Spa: 15.51(4)k(2) 16
  Item: A fence, wall, or other means of enclosure shall have no openings that would allow the passage of a 4-inch sphere, and shall not be easily climbable by toddlers.
  Comment: Please ensure the gap at the bottom of the fence behind the chemical room is addressed so that it does not exceed 4 inches and is ready for the 2027 season.
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).