Swimming Pool / Spa Inspection Report Jones County Environmental Services 105 Broadway Place, Suite 11 Anamosa, IA 52205 Phone: (319) 462-4715 Fax: (319) 462-5302 E-mail: environmental@co.jones.ia.us |
Facility Name: Camp Courageous
Title: CPO Registration No: SP53-004-100 \ SP53-004-101 Type: Routine |
Name: | Ind. Pool >= 1500 | Ind. Pool < 1500 |
---|---|---|
Registration No: | SP53-004-100 | SP53-004-101 |
Area (Sq. ft.): | 3712 | 1080 |
Volume (Gallons): | 166367 | 24300 |
Filter Type: | Sand | Sand |
Filter Rate: | ||
Turnover Rate: | ||
Chlorine (Free): | 3.0 | 5.6 |
ORP: | 790 / 7.44 | 806 / 7.34 |
Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
||
Chlorine (Total): | 3.2 | 5.8 |
Chlorine (Combined): | 0.2 | 0.2 |
Bromine: | NA | NA |
Pool: 2-18ppm Spa: 4-18ppm | ||
Cyanuric Acid: | NA | NA |
Must be less than 80 ppm | ||
pH: | 7.2 | 7.2 |
Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
||
Total Alkalinity: | 110 | 70 |
Calcium Hardness: | 270 | 480 |
Name: | Ind. Pool >= 1500 | Ind. Pool < 1500 |
---|---|---|
Registration No: | SP53-004-100 | SP53-004-101 |
Temperature (F): | 82.3 | 88.8 |
Spa must not exceed 104° | ||
Type of Disinfectant: | Chlorine Briquettes | Chlorine Briquettes |
Disinfection make and model: | Prominent | Prominent |
Drain Cover make and model: | Waterway | Aquastar |
Drain Cover exp. date: | 1/28/2029 | 1/26/2027 |
CPO: | Lisa | Jocelyn |
CPO exp. date: | 1/3/2029 | 11/17/2026 |
1. Facility in compliance with smoking ban? | |
( If no, complete complaint form ) |
Notes: :
Routine inspection today.
No violations, just a couple of notes:
pH is lower than what the controller reads in the lap pool. You may benefit from cleaning the probes with dish soap and a toothbrush.
Two submerged lights are still out in the lap pool. Replacement bulbs are not available and LED don't fit. I will contact the State for advice.
Thank you.
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).