Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: AmericInn Lodge & Suites
Address: 8910 6th St SW
Cedar Rapids, IA  52404
Person Contacted: Todd Summers
Title: CPO
Registration No: SP57-103-100 \ SP57-103-101
Type: Routine

Water Quality Information
Name: Pool Indoor Spa
Registration No: SP57-103-100 SP57-103-101
Area (Sq. ft.): 565 136
Volume (Gallons): 17000 2500
Filter Type: Sand Sand
Filter Rate:
Turnover Rate:
Chlorine (Free): 6.0 3.4
ORP: 701 / 7.32 701/ / 7.31
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total): 6.2 4.3
Chlorine (Combined): 0.2 0.8
Bromine: NA NA
Pool: 2-18ppm Spa: 4-18ppm
Cyanuric Acid: NA NA
Must be less than 80 ppm
pH: 7.4 7.2
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 50 30
Calcium Hardness: 270 650

 

Water Quality Information (continued)
Name: Pool Indoor Spa
Registration No: SP57-103-100 SP57-103-101
Temperature (F): 79.9 99.6
Spa must not exceed 104°
Type of Disinfectant: Chlorine Puck Chlorine Puck
Disinfection make and model: EcoLab N-290 EcoLab N-290
Drain Cover make and model: Aquastar Aquastar
Drain Cover exp. date: 1/10/2024- Expired 1/10/2024- Expired
CPO: Todd Summers Same
CPO exp. date: 5/1/2029 Same

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: :

Routine inspection today.

Please send me a text or email once items below are complete.

Thank you.

# Section Reference Ref. Page
1) Safety Pool: 15.4(4)h 18 and 19
  Item: All drains shall be VGB compliant and within their life expectancy date
  Comment: Drain covers are expired. New ones are on order. Existing ones appear to be in good repair and securely anchored. Replace within 30 days.
   
2) Safety Spa: 15.51(4)l 16
  Item: The agitation system control (timer) shall be installed out of the reach of persons in the spa. The "on" cycle for the agitation system shall be no more than ten minutes
  Comment: Timer does not work, but a new one is in house den will be installed tomorrow..
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).