Swimming Pool / Spa Inspection Report Linn County Public Health 1020 - 6th Street SE Cedar Rapids, IA 52401 Phone: (319) 892-6000 Fax: (319) 892-6099 E-mail: health@linncountyiowa.gov |
Facility Name: Sleep Inn & Suites
Title: GM Registration No: SP57-100-100 \ SP57-100-101 Type: Routine |
Name: | Indoor Pool < 1500 sq ft | Indoor Spa |
---|---|---|
Registration No: | SP57-100-100 | SP57-100-101 |
Area (Sq. ft.): | 435 | 80 |
Volume (Gallons): | 16000 | 1800 |
Filter Type: | Sand | Sand |
Filter Rate: | XX | XX |
Turnover Rate: | XX | XX |
Chlorine (Free): | 2.2 | 2.0 |
ORP: | 792 / 7.5 | 802 / 7.5 |
Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
||
Chlorine (Total): | 2.6 | 2.2 |
Chlorine (Combined): | 0.4 | 0.4 |
Bromine: | NA | NA |
Pool: 2-18ppm Spa: 4-18ppm | ||
Cyanuric Acid: | NA | NA |
Must be less than 80 ppm | ||
pH: | 7.6 | 7.8 |
Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
||
Total Alkalinity: | 100 | 60 |
Calcium Hardness: | 600 | 300 |
Name: | Indoor Pool < 1500 sq ft | Indoor Spa |
---|---|---|
Registration No: | SP57-100-100 | SP57-100-101 |
Temperature (F): | 85.5 | 99.5 |
Spa must not exceed 104° | ||
Type of Disinfectant: | Chlorine | Chlorine |
Disinfection make and model: | Chemtrol 250 | Chemftro 250 |
Drain Cover make and model: | Aquastar | Aquastar |
Drain Cover exp. date: | 4/29/2024 | 4/29/2024 |
CPO: | Ricky | Ricky |
CPO exp. date: | April 2028 | April 2028 |
1. Facility in compliance with smoking ban? | |
( If no, complete complaint form ) |
Notes: :
Routine inspection today.
Please see notes below.
Thank you for taking your job as the CPO seriously and correcting all of the concerns that were here prior to your arrival. You have done an excellent job!
Keep up the good work!
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Safety | Pool: | 15.4(6)l | 13 |
Spa: | 15.4(6)l | 19 | ||
Item: The facility management shall develop a written emergency plan. The plan shall include, but may not be limited to, actions to be taken in cases of drowning, serious illness or injury, chemical-handling accidents, weather emergencies, and other serious incidents. The emergency plan shall be reviewed with the facility staff at least once a year, and the dates of review or training shall be recorded in the pool records | ||||
Comment: Have this and SDS sheets for the pool in one binder with a sign-off sheet for both that all staff signs now and annually thereafter. | ||||
2) | Safety | Pool: | 15.4(4)a(3) | 12 |
Spa: | 15.51(4)a(3) | 13 | ||
Item: Material safety data sheets (MSDS) for the chemicals used at the pool or spa shall be at the facility in a location known and readily accessible to the facility staff. The SDS sheets shall be reviewed with the facility staff at least once a year, and the dates of review or training shall be recorded in the pool records | ||||
Comment: EcoLab should provide you with these sheets. Place them and an Emergency Action Plan for the pool in one binder with a sign-off sheet for both that all staff signs now and annually thereafter. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).