Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: Tru by Hilton
Address: 3900 Westdale Parkway SW
Cedar Rapids, IA  52404
Person Contacted: Andrew Leonard
Title: CPO
Registration No: SP57-116-100
Type: Routine

Water Quality Information
Name: Indoor Pool < 150
Registration No: SP57-116-100
Area (Sq. ft.): 352
Volume (Gallons): 1408
Filter Type: Sand
Filter Rate:
Turnover Rate:
Chlorine (Free): 3.0
ORP: 781/7.41 / 3.1ppm
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total): 3.6
Chlorine (Combined): 0.6
Bromine: NA
Pool: 2-18ppm Spa: 4-18ppm
Water Quality Information (continued)
Cyanuric Acid: NA
Must be less than 80 ppm
pH: 7.4
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 50
Calcium Hardness: 170
Temperature (F): 84.8
Spa must not exceed 104°
Type of Disinfectant: Saline
Disinfection make and model: EcoLab Pure Comfort
Drain Cover make and model: Waterway 9x9 x2
Drain Cover exp. date: 1/30/2025
CPO:
CPO exp. date:

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: .
Please email a letter of correction stating how the violations listed below have been and/or will be corrected to diane.midcalf@linncountyiowa.gov within 30 days of this inspection.

# Section Reference Ref. Page
1) Management/Personnel Pool: 15.4(2)e 8
  Item: The disinfectant and pH in the pool water shall be manually tested or the ORP and pH of the swimming pool water shall be visually read and documented each day within one-half hour of the swimming pool opening, and at intervals not to exceed four hours thereafter until the swimming pool closes for the day. Visual ORP and pH in lieu of some of the manual tests are sufficient, but the swimming pool water shall be tested manually for disinfectant and pH at least twice per day. When manual tests are done, the manual test results and the visual readings for the ORP and pH shall be recorded.
  Comment: Please retrain staff on manual water testing and documenting readings and ensure they are getting done at the appropriate times.
   
2) Safety Pool: 15.4(4)a(3) 12
Spa: 15.51(4)a(3) 13
  Item: Material safety data sheets (MSDS) for the chemicals used at the pool or spa shall be at the facility in a location known and readily accessible to the facility staff. The SDS sheets shall be reviewed with the facility staff at least once a year, and the dates of review or training shall be recorded in the pool records
  Comment: Get these from Rick and please have all staff sign off on reviewing then now and annually thereafter.
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).