Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: Coe College Pool
Address: 1220 1st Ave NE
Cedar Rapids, IA  52402
Person Contacted: John Long
Title: CPO
Registration No: SP57-011-100
Type: Routine

Water Quality Information
Name: Indoor Pool >= 1500 sq ft
Registration No: SP57-011-100
Area (Sq. ft.): 11160
Volume (Gallons): 440000
Filter Type: Sand
Filter Rate:
Turnover Rate:
Chlorine (Free): 1.8
ORP: 817 / 7.5
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total): 2.0
Chlorine (Combined): 0.2
Bromine: NA
Pool: 2-18ppm Spa: 4-18ppm
Water Quality Information (continued)
Cyanuric Acid: NA
Must be less than 80 ppm
pH: 7.2
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 130
Calcium Hardness: 310
Temperature (F):
Spa must not exceed 104°
Type of Disinfectant: Sodium Hypo
Disinfection make and model: Pulsar 3 PS 5000
Drain Cover make and model: Eureka MFG A112, 19.8-2007
Drain Cover exp. date: 6/1/2029
CPO:
CPO exp. date:

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: :
Routine inspection today.

Please email a letter of correction stating how the violations listed below have been and/or will be corrected to diane.midcalf@linncountyiowa.gov within 30 days of this inspection.

Also, please be sure that the water is being tested either every 4 hours or before each person enters the water. Thank you.

# Section Reference Ref. Page
1) Management/Personnel Pool: 15.4(6)f(6) 24
Spa: 15:51(5)e(8) 17
  Item: Monthly ground fault circuit interrupter (GFCI) shall be included in Operational Records
   
2) Safety Pool: 15.4(4)b(2) 13
  Item: Pool ladders, ramps, handrails, and grab rails shall be securely anchored.
   
3) Safety Pool: 15.4(6)k 25
Spa: 15.51(5)i 18
  Item: Each member of staff shall sign off that they have reviewed SDS sheets along with the Emergency Action Plan annually.
  Comment: This shall include the maintenance staff, guards and coaches.
   
4) Safety Pool: 15.4(4)m(2) 17
  Item: Fully submerged lighting in a pool or spa shall be in working order.
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).