Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: YMCA Camp Wapsie
Address: 2174 Wapsie Y Rd
Coggon, IA  52218
Person Contacted: Brian Harkness
Title: Maintenance
Registration No: SP57-025-100
Type: Routine

Water Quality Information
Name: Outdoor Pool >= 1500 sq ft
Registration No: SP57-025-100
Area (Sq. ft.): 3150
Volume (Gallons): 119500
Filter Type: Sand
Filter Rate:
Turnover Rate:
Chlorine (Free): 2.6
ORP: 658
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total):
Chlorine (Combined): 2.8
Bromine: NA
Pool: 2-18ppm Spa: 4-18ppm
Water Quality Information (continued)
Cyanuric Acid: <30
Must be less than 80 ppm
pH: 7.8
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 160
Calcium Hardness: 350
Temperature (F): 81
Spa must not exceed 104°
Type of Disinfectant: Chlorine
Disinfection make and model: ACCO Liquid
Drain Cover make and model: Hayward WGZ1031BHF2
Drain Cover exp. date: 4/1/2024
CPO:
CPO exp. date:

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: * Check to be sure sand gauges are working

* Document ORP and pH from feeder with manual tests. Ensure they are all in operating range.

* I will email you monthly water sample options

# Section Reference Ref. Page
1) Safety Pool: 15.4(6)l 13
Spa: 15.4(6)l 19
  Item: The facility management shall develop a written emergency plan. The plan shall include, but may not be limited to, actions to be taken in cases of drowning, serious illness or injury, chemical-handling accidents, weather emergencies, and other serious incidents. The emergency plan shall be reviewed with the facility staff at least once a year, and the dates of review or training shall be recorded in the pool records
  Comment: Please add weather emergencies to your EAP. Also have all staff sign off on this now and at the beginning of the camping year going forward.
   
2) Safety Pool: 15.4(4)a(3) 12
Spa: 15.51(4)a(3) 13
  Item: Material safety data sheets (MSDS) for the chemicals used at the pool or spa shall be at the facility in a location known and readily accessible to the facility staff. The SDS sheets shall be reviewed with the facility staff at least once a year, and the dates of review or training shall be recorded in the pool records
  Comment: Have all staff sign off on this now and at the beginning of the camping season going forward
   
3) Safety Pool: 15.4(4)m(1) 22
Spa: 15.51(4)j(1) 15
  Item: Each electrical outlet in the deck, shower room, and pool water treatment equipment areas of a swimming pool or spa shall be equipped with a properly installed ground fault circuit interrupter (GFCI) at the outlet or at the breaker serving the outlet, and shall be tested at least once a month. Testing dates and results shall be recorded in the pool records.
  Comment: Document this on your log sheet once per month.
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).