Swimming Pool / Spa Inspection Report Jones County Environmental Services 105 Broadway Place, Suite 11 Anamosa, IA 52205 Phone: (319) 462-4715 Fax: (319) 462-5302 E-mail: environmental@co.jones.ia.us |
Facility Name: Anamosa Aqua Court
Title: Director Registration No: SP53-007-100 \ SP53-007-102 \ SP53-007-101 Type: Routine |
Name: | Out. Pool >= 1500 | Out. Wading | Out. Waterslide |
---|---|---|---|
Registration No: | SP53-007-100 | SP53-007-102 | SP53-007-101 |
Area (Sq. ft.): | |||
Volume (Gallons): | 200000 | 3675 | |
Filter Type: | Sand | ||
Filter Rate: | |||
Turnover Rate: | |||
Chlorine (Free): | 3.0 | ||
ORP: | 741/7.2 | ||
Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
|||
Chlorine (Total): | 3.0 | ||
Chlorine (Combined): | 0 | ||
Bromine: | NA | ||
Pool: 2-18ppm Spa: 4-18ppm | |||
Cyanuric Acid: | <30 | ||
Must be less than 80 ppm | |||
pH: | 7.4 | ||
Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
|||
Total Alkalinity: | 130 | ||
Calcium Hardness: | 450 |
Name: | Out. Pool >= 1500 | Out. Wading | Out. Waterslide |
---|---|---|---|
Registration No: | SP53-007-100 | SP53-007-102 | SP53-007-101 |
Temperature (F): | 78.4 | ||
Spa must not exceed 104° | |||
Type of Disinfectant: | Chlorine | ||
Disinfection make and model: | Pulsar Precision Liquid | ||
Drain Cover make and model: | Unknown | ||
Drain Cover exp. date: | 5/17/2022 | ||
CPO: | |||
CPO exp. date: |
1. Facility in compliance with smoking ban? | |
( If no, complete complaint form ) |
Notes: Please email a letter of correction stating how the violations listed below have been and/or will be corrected to diane.midcalf@linncounty.org within 30 days of this inspection. Call Diane at 319-521-3066 with questions. Thank you!
The baby pool is not registered with IDPH and is not in use however, it does have water in it. Please have the gate to this locked unless it is in working order and registered with IDPH.
Address the leak at the pump for the waterslide.
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Management/Personnel | Pool: | 15.4(6)f(6) | 24 |
Spa: | 15:51(5)e(8) | 17 | ||
Item: Monthly ground fault circuit interrupter (GFCI) shall be included in Operational Records | ||||
Comment: Record this monthly | ||||
2) | Management/Personnel | Pool: | 15.4(2)e | 10 and 11 |
Spa: | 15.51(2)e | 11 and 12 | ||
Item: Not tested/recorded as often as necessary in Operation Records | ||||
Comment: Testing records are not complete. Chlorine and pH should be recorded within 30 minutes of opening the pool for the day and in intervals not to exceed 4 hours after. Combined Chlorine, Total Chlorine, Alkalinity, and Cyanuric Acid should be recorded weekly. Calcium Hardness and Bacterial Analysis that gets sent to the State Hygenic Laboratory should be recorded at least monthly. | ||||
3) | Management/Personnel | Pool: | 15.4(6)b | 23 |
Item: "Pool Rules" signage incorrectly posted. Rules sign shall include No diving in shallow end, No horseplay, and No running on deck. Post conspicuously at a minimum of 2 locations within the swimming pool enclosure. | ||||
4) | Management/Personnel | Pool: | 15.4(6)e | 24 |
Item: "Water Slide Rules" signage incorrectly posted | ||||
Comment: Rules and restrictions for the use of a water slide shall be posted near the slide. The rules shall address the following as applicable: (1) Use limits. (2) Attire. (3) Riding restrictions. (4) Water depth at exit. (5) Special rules to accommodate unique aspects of the attraction. (6) Special warnings about the relative degree of difficulty. | ||||
5) | Safety | Pool: | 15.4(4)b(2) | 13 |
Item: Pool ladders, ramps, handrails, and grab rails shall be securely anchored. | ||||
Comment: Tighten the ladder in the water slide area. | ||||
6) | Safety | Pool: | 15.4(6)k | 25 |
Spa: | 15.51(5)i | 18 | ||
Item: Copies of MSDS sheets shall be available for employee review. Each member of staff shall review MSDS annually. | ||||
Comment: Add this to your Emergency Action Plan sign-off sheet. | ||||
7) | Structure/Diving | Pool: | 15.4(4)c(9) | 14 |
Item: A platform or diving board that is 32 inches or more above the swimming pool deck shall have a guardrail on both sides. The guardrails shall be at least 36 inches high and shall extend to the edge of the deck. The guardrails shall have at least one horizontal mid-bar. | ||||
Comment: Tighten the bolt underneath the diving board closest to the water slide's west guardrail, it is loose. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).