Swimming Pool / Spa Inspection Report Linn County Public Health 1020 - 6th Street SE Cedar Rapids, IA 52401 Phone: (319) 892-6000 Fax: (319) 892-6099 E-mail: health@linncounty.org |
Facility Name: Fairfield Inns & Suites
Title: N/A Registration No: SP57-111-100 \ SP57-111-101 Type: Routine |
Name: | Indoor Pool < 1500 sq ft | Indoor Spa |
---|---|---|
Registration No: | SP57-111-100 | SP57-111-101 |
Area (ft.): | 273 | 52 |
Volume (Sq. ft.): | 7549 | 909 |
Filter Type: | sandfilter | sand |
Filter Rate: | ||
Turnover Rate: | ||
Chlorine (Free): | 0 | .2 |
ORP: | 360 | 350 |
Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
||
Chlorine (Total): | ||
Chlorine (Combined): | ||
Bromine: | ||
Pool: 2-18ppm Spa: 4-18ppm | ||
Cyanuric Acid: | ||
Must be less than 80 ppm | ||
pH: | 7.4 | 7.4 |
Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
||
Total Alkalinity: | ||
Calcium Hardness: |
Name: | Indoor Pool < 1500 sq ft | Indoor Spa |
---|---|---|
Registration No: | SP57-111-100 | SP57-111-101 |
Temperature (F): | 105.8 | |
Spa must not exceed 104° | ||
Type of Disinfectant: | chlorine | chlorine |
1. Facility in compliance with smoking ban? | |
( If no, complete complaint form ) |
Notes: POOL AND SPA ARE CLOSED AT TIME OF INSPECTION. CHLORINE WAS NOT PRESENT IN EITHER BODY OF WATER AT OR NEAR THE REQUIRED LEVELS. PHYSICAL RECHECK WILL NEED TO BE COMPLETED BEFORE OPENING THE POOL AND SPA.
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Management/Personnel | Pool: | 15.4(6)f | 24 |
Spa: | 15.51(5)e | 17 | ||
Comment: unable to find complete records for pool and spa. | ||||
Item: CPO must keep previous 12 months of Operational Records | ||||
2) | Management/Personnel | Pool: | 15.4(6)f | 24 |
Spa: | 15.51(5)e | 17 | ||
Comment: no information available for chemical additions, complaints, injuries, or daily temps. | ||||
Item: Records shall include results of chemical tests, results of microbial analyses, reports of complaints/injuries/illnesses, daily water temp. (spa), dates of draining/cleaning, and dates of review of MSDS | ||||
3) | Filtration/Recirculation | Pool: | 15.4(1)b(4) | 8 |
Spa: | 15.51(1)e | 9 | ||
Comment: no weirs in skimmers | ||||
Item: Skimmer shall have an easily removable basket/screen upstream from any valve and have a Self-adjusting weir in place | ||||
4) | Water Quality | Pool: | 15.4(2)f | 11 and 12 |
Spa: | 15.51(2)f | 12 | ||
Comment: Kit for testing is expired on 12/16 | ||||
Item: Each facility shall have functional water testing equipment for free chlorine and combined chlorine, or total bromine; pH; total alkalinity; calcium hardness; and cyanuric acid | ||||
5) | Water Quality | Spa: | 15.51(3)b(2) | 12 |
Comment: no documentation of draining spa | ||||
Item: A spa containing 500 gal of water or less shall be drained once a week, a spa over 500 gal to 2000 gal shall be drained once every 2 weeks, and a spa over 2000 gal shall be drained once every 3 weeks | ||||
6) | Water Quality | Pool: | 15.4(1)c | 8 |
Spa: | 15.51(1)f | 9 | ||
Comment: no air gap on discharge piping | ||||
Item: Wastewater - Wastewater and backwash water shall be discharged through an air break or an air gap | ||||
7) | Safety | Pool: | 15.4(4)f(4) | 17 |
Comment: 2 incomplete first aid kits. | ||||
Item: A first-aid kit shall be equipped with: band-aids, sterile 4x4 bandage compress, self-adhering gauze bandage, disposable gloves, and a chemical cold press. | ||||
8) | Safety | Spa: | 15.51(4)c(1) | 13 |
Comment: The temp on the spa heater was reading 98 when our thermometer reads 105.8 | ||||
Item: A thermometer shall be available to measure temperatures in the range of 80 degrees to 120 degrees. Spa shall be closed if the temperature is over 104 degrees F. | ||||
9) | Safety | Pool: | 15.4(4)b(8) | 14 |
Comment: ladder in pool slip resistant but has no color contrast. | ||||
Item: When stairs are provided for entry into a swimming pool, a stripe at least 1 inch wide of a color contrasting with the step surface and with the swimming pool floor shall be marked at the top front edge of each tread. The stripe shall be slip-resistant. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).