Swimming Pool / Spa Inspection Report Linn County Public Health 1020 - 6th Street SE Cedar Rapids, IA 52401 Phone: (319) 892-6000 Fax: (319) 892-6099 E-mail: health@linncountyiowa.gov |
Facility Name: Bowman Woods Swim & Racquet Club
Title: CPO Registration No: SP57-003-102 \ SP57-003-100 \ SP57-003-101 Type: Routine |
Name: | Outdoor Waterslide-1st into pool | Out. Pool >= 1500 | Out. Wading Pool2 |
---|---|---|---|
Registration No: | SP57-003-102 | SP57-003-100 | SP57-003-101 |
Area (Sq. ft.): | 3000 | 314 | |
Volume (Gallons): | 94000 | 2350 | |
Filter Type: | |||
Filter Rate: | |||
Turnover Rate: | |||
Chlorine (Free): | 5.2 | 5.4 | 3.6 |
ORP: | 685 | 685 | 685 |
Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
|||
Chlorine (Total): | |||
Chlorine (Combined): | 0 | 0 | 0 |
Bromine: | |||
Pool: 2-18ppm Spa: 4-18ppm | |||
Cyanuric Acid: | <30 | <30 | <30 |
Must be less than 80 ppm | |||
pH: | 7.6 | 7.6 | 7.6 |
Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
|||
Total Alkalinity: | 100 | 100 | 100 |
Calcium Hardness: |
Name: | Outdoor Waterslide-1st into pool | Out. Pool >= 1500 | Out. Wading Pool2 |
---|---|---|---|
Registration No: | SP57-003-102 | SP57-003-100 | SP57-003-101 |
Temperature (F): | |||
Spa must not exceed 104° | |||
Type of Disinfectant: | |||
Disinfection make and model: | |||
Drain Cover make and model: | |||
Drain Cover exp. date: | |||
CPO: | |||
CPO exp. date: |
1. Facility in compliance with smoking ban? | |
( If no, complete complaint form ) |
Notes: FACILITY IS APPROVED TO RE-OPEN.
Recheck inspection completed to re-open pool. Items from previous inspection that have been corrected have been removed from report. All remaining items must still be corrected.
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Management/Personnel | Pool: | 15.4(6)l | 25 |
Spa: | 15.51(5)j | 18 | ||
Item: A written emergency plan shall be provided and reviewed annually | ||||
Comment: Emergency plan is not reviewed annually. | ||||
2) | Management/Personnel | Pool: | 15.4(6)f | 24 |
Spa: | 15.51(5)e | 17 | ||
Item: CPO must keep previous 12 months of Operational Records | ||||
Comment: Previous 12 months of operational records were not able to be located. | ||||
3) | Management/Personnel | Pool: | 15.4(6)f | 24 |
Spa: | 15.51(5)e | 17 | ||
Item: Records shall include results of chemical tests, results of microbial analyses, reports of complaints/injuries/illnesses, daily water temp. (spa), dates of draining/cleaning, and dates of review of MSDS | ||||
Comment: Records did not include results of microbial analyses, dates of draining/cleaning, and dates of review of MSDS. | ||||
4) | Management/Personnel | Pool: | 15.4(6)f(4) | 24 |
Spa: | 15.51(5)e(5) | 17 | ||
Item: Dates and quantities of chemical additions (superchlorination) must be included in Operational Records | ||||
Comment: Dates and quantities of chemical additions is not included in operational records. | ||||
5) | Management/Personnel | Pool: | 15.4(6)f(6) | 24 |
Spa: | 15:51(5)e(8) | 17 | ||
Item: Monthly ground fault circuit interrupter (GFCI) shall be included in Operational Records | ||||
Comment: Monthly ground fault circuit interrupter testing is not included in operational records. | ||||
6) | Management/Personnel | Pool: | 15.4(6)f(5) | 24 |
Spa: | 15.51(5)e(6) | 17 | ||
Item: Dates when filters are backwashed, cleaned, or changed included in Operational Records | ||||
Comment: Dates when filters are backwashed, cleaned, or changed is not included in operational records. | ||||
7) | Management/Personnel | Pool: | 15.4(2)e | 10 and 11 |
Spa: | 15.51(2)e | 11 and 12 | ||
Item: Not tested/recorded as often as necessary in Operation Records | ||||
Comment: Testing not being recorded/completed as often as necessary. | ||||
8) | Management/Personnel | Pool: | 15.4(6)b | 23 |
Item: "Pool Rules" signage incorrectly posted. Rules sign shall include No diving in shallow end, No horseplay, and No running on deck. Post conspicuously at a minimum of 2 locations within the swimming pool enclosure. | ||||
Comment: "Pool Rules" signage not posted conspicuously in at least 2 locations. | ||||
9) | Management/Personnel | Pool: | 15.4(6)e | 24 |
Item: "Water Slide Rules" signage incorrectly posted | ||||
Comment: "Water Slide Rules" signage incorrectly posted. | ||||
10) | Marking | Pool: | 15.4(4)i(2) | 19 |
Spa: | 15.51(4)g | 15 | ||
Item: Pool and Spa walls and floor shall be smooth and easily cleanable | ||||
Comment: Missing significant amount of tiling around interior edge of pool. | ||||
11) | Safety | Pool: | 15.4(4)b(2) | 13 |
Item: Pool ladders, ramps, handrails, and grab rails shall be securely anchored. | ||||
Comment: Pool ladders are loose. | ||||
12) | Safety | Pool: | 15.4(4)d(5) | 16 |
Item: Each water slide shall have a minimum of two attendants, one stationed at the top of the slide and one at the bottom of the slide. | ||||
Comment: Water slide does not currently have any attendants and no alternate program has been approved for use. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).