Swimming Pool / Spa Inspection Report Jones County Environmental Services 105 Broadway Place, Suite 11 Anamosa, IA 52205 Phone: (319) 462-4715 Fax: (319) 462-5302 E-mail: environmental@co.jones.ia.us |
Facility Name: Camp Wyoming
Title: Camp Director & CPO Registration No: SP53-005-100 Type: Routine |
|
|
Notes: Several repeat violations. Must correct before next pool season. To repair pool, Camp Wyoming raised money. Needs more funding.
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Management/Personnel | Pool: | 15.4(6)f(4) | 24 |
Spa: | 15.51(5)e(5) | 17 | ||
Item: Dates and quantities of chemical additions (superchlorination) must be included in Operational Records | ||||
Comment: Record date and amounts of chemicals added to the pool. | ||||
2) | Management/Personnel | Pool: | 15.4(6)i | 25 |
Spa: | 15.51(5)g | 18 | ||
Item: A permanent manual of operation shall be kept in facility | ||||
3) | Filtration/Recirculation | Pool: | 15.4(4)h | 18 |
Spa: | 15.51(4)f | 14 | ||
Item: Each outlet including main drains shall be designed to prevent user entrapment. Spa or pool shall be closed if drain is broken. | ||||
Comment: VGB drain expired 5-9-2014. MUST REPLACE BEFORE OPEN NEXT YEAR (pool no longer in operation this year). | ||||
4) | Filtration/Recirculation | Pool: | 15.4(1)b(4) | 8 |
Spa: | 15.51(1)e | 9 | ||
Item: Skimmer shall have an easily removable basket/screen upstream from any valve and have a Self-adjusting weir in place | ||||
Comment: Missing weir doors on several skimmers. Need Replaced. REPEAT VIOLATION | ||||
5) | Decks | Pool: | 15.5(4)b | 29 |
Spa: | 15.52(4)a | 22 | ||
Item: Decks shall be constructed of stable, nontoxic, durable, and impervious materials and shall be provided with a slip-resistant surface | ||||
Comment: Deck is cracked and no longer durable/impervious. Needs Replaced. REPEAT VIOLATION. | ||||
6) | Safety | Pool: | 15.4(4)l(1) | 19 |
Item: A swimming pool shall be enclosed by a fence, wall, building, or combination thereof not less than 4 ft. high. | ||||
Comment: Fence near chemical storage has larger than 4 inch gap. Needs Repaired. REPEAT VIOLATION. | ||||
7) | Safety | Pool: | 15.4(4)k(1) | 21 |
Spa: | 15.51(4)h(1) | 15 | ||
Item: The area around and inside the pool/spa shall have no sharp edges | ||||
Comment: Large crack in pool. Must Repair. REPEAT VIOLATION. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).