Swimming Pool / Spa Inspection Report Linn County Public Health 1020 - 6th Street SE Cedar Rapids, IA 52401 Phone: (319) 892-6000 Fax: (319) 892-6099 E-mail: health@linncountyiowa.gov |
Facility Name: Parkridge Condominium
Title: CPO Registration No: SP57-063-100 |
|
|
Notes: Chlorine level was a little low a time of inspection as well as the calcium hardness. Cyanuric acid was tested high and should be lowered.
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Management/Personnel | Pool: | 15.4(6)f | 24 |
Spa: | 15.51(5)e | 17 | ||
Item: Records shall include results of chemical tests, results of microbial analyses, reports of complaints/injuries/illnesses, daily water temp. (spa), dates of draining/cleaning, and dates of review of MSDS | ||||
Comment: Accident log was not found in records. Must have a log for accidents/injury's and keep in the log book. | ||||
2) | Management/Personnel | Pool: | 15.4(6)i | 25 |
Spa: | 15.51(5)g | 18 | ||
Item: A permanent manual of operation shall be kept in facility | ||||
Comment: Operation manual was not found for the pump. Must have operation manual at all times for reference. | ||||
3) | Management/Personnel | Pool: | 15.4(6)l | 25 |
Spa: | 15.51(5)j | 18 | ||
Item: A written emergency plan shall be provided and reviewed annually | ||||
Comment: Do not have emergency action plans (EAP) in log book. Must have a emergency plan for each of the following events: chemical spill, drowning, serious injury or illness, and weather emergencies. EAP's must be reviewed annually and date must be recorded in log book. | ||||
4) | Management/Personnel | Pool: | 15.4(6)f(6) | 24 |
Spa: | 15:51(5)e(8) | 17 | ||
Item: Monthly ground fault circuit interrupter (GFCI) shall be included in Operational Records | ||||
Comment: GFI testing was not recorded in the log book. Must test all electrical outlets in pool area once per month and record date in log book. | ||||
5) | Management/Personnel | Pool: | 15.4(4)h(1) | 18 |
Spa: | 15.51(4)f | 14 | ||
Item: Main drain and SVRS documentation (VGB) with dates of installation must be kept in facility. Each SVRS shall be tested monthly and the test dates recorded | ||||
Comment: Drain covers do not have life expectancy recorded in the log book. Must have the life expectancy of drain covers documented in the log book. | ||||
6) | Management/Personnel | Pool: | 15.4(2)e | 10 and 11 |
Spa: | 15.51(2)e | 11 and 12 | ||
Item: Not tested/recorded as often as necessary in Operation Records | ||||
Comment: Facility was not testing within 1/2 hour of opening, and was not testing every 4 hours. Water chemical tests must be conducted at least once every 4 hours, and within 1/2 hour of opening. Pool hours are 9am to 9pm currently, but will be changed due to availability. | ||||
7) | Marking | Pool: | 15.4(4)i(2) | 19 |
Spa: | 15.51(4)g | 15 | ||
Item: Pool and Spa walls and floor shall be smooth and easily cleanable | ||||
Comment: Pool shell appears to be peeling paint. Pool shell must be resurfaced or refinished to make surface easily cleanable. | ||||
8) | Safety | Pool: | 15.4(4)f(4) | 17 |
Item: A swimming pool facility shall have a first-aid kit. Where lifeguards are not provided, the first-aid kit shall be prominently mounted in the swimming pool enclosure, or a sign stating its location shall be posted near the swimming pool. | ||||
Comment: Do not have a sign stating where the first aid kit may be found. Must have a sign stating where the first aid kit can be found or have the kit mounted inside the enclosure. | ||||
9) | Safety | Pool: | 15.4(4)b(2) | 13 |
Item: Pool ladders, ramps, handrails, and grab rails shall be securely anchored. | ||||
Comment: Ladder is loose. Must securely anchor the ladder to prevent accident or injury. | ||||
10) | Safety | Pool: | 15.4(4)b(3) | 13 |
Item: The lower end of each ladder rail shall be securely covered with a smooth nonmetallic cap. | ||||
Comment: Missing end cap on right side of the ladder. The end of the ladder must be covered with a smooth, non-metallic end cap. | ||||
11) | Safety | Pool: | 15.4(6)k | 25 |
Spa: | 15.51(5)i | 18 | ||
Item: Copies of MSDS sheets shall be available for employee review. Each member of staff shall review MSDS annually. | ||||
Comment: Annual review of MSDS was not in log book. Must review the MSDS sheets annually and record date in log book. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).