Swimming Pool / Spa Inspection Report Jones County Environmental Services 105 Broadway Place, Suite 11 Anamosa, IA 52205 Phone: (319) 462-4715 Fax: (319) 462-5302 E-mail: environmental@co.jones.ia.us |
Facility Name: Monticello Aquatic Center
Title: CPO Registration No: SP53-002-100 \ SP53-002-101 \ SP53-002-102 Type: Routine |
Name: | Out. Pool >= 1500 | Out. Wad > 500 | Out. Waterslide |
---|---|---|---|
Registration No: | SP53-002-100 | SP53-002-101 | SP53-002-102 |
Area (Sq. ft.): | 6000 | 900 | |
Volume (Gallons): | 40000 | ||
Filter Type: | |||
Filter Rate: | |||
Turnover Rate: | |||
Chlorine (Free): | 2.6 | 2.8 | 2.6 |
ORP: | 717 | 703 | 717 |
Pool: 1-8ppm, ORP 700-880 mV If less than 0.6ppm or greater than 8.0ppm = closure Spa: 2-8 ppm ORP 700-880 mV If less than 1.0ppm or greater than 8.0ppm = closure |
|||
Chlorine (Total): | |||
Chlorine (Combined): | |||
Bromine: | |||
Pool: 2-18ppm Spa: 4-18ppm | |||
Cyanuric Acid: | <30 | <30 | <30 |
Must be less than 80 ppm | |||
pH: | 7.4 | 7.4 | 7.4 |
Pool and Spa: 7.2ppm-7.8ppm If less than 6.8 or greater than 8.2 = closure |
|||
Total Alkalinity: | 70 | 60 | 70 |
Calcium Hardness: |
Name: | Out. Pool >= 1500 | Out. Wad > 500 | Out. Waterslide |
---|---|---|---|
Registration No: | SP53-002-100 | SP53-002-101 | SP53-002-102 |
Temperature (F): | |||
Spa must not exceed 104° | |||
Type of Disinfectant: | |||
Disinfection make and model: | |||
Drain Cover make and model: | |||
Drain Cover exp. date: | |||
CPO: | |||
CPO exp. date: |
1. Facility in compliance with smoking ban? | |
( If no, complete complaint form ) |
Notes: Provided operator with information regarding emergency action plan. Discussed requirement of having lifeguard posted for wading pool while in operation.
# | Section | Reference | Ref. Page | |
---|---|---|---|---|
1) | Management/Personnel | Pool: | 15.4(6)h | 25 |
Item: Copies of certificates (CPO, Lifeguard, First Aid, Basic Water Rescue, and CPR) kept in facility | ||||
Comment: Lifeguard certifications were not at facility. | ||||
2) | Management/Personnel | Pool: | 15.4(6)l | 25 |
Spa: | 15.51(5)j | 18 | ||
Item: A written emergency plan shall be provided and reviewed annually | ||||
Comment: No emergency plan available at time of inspection. | ||||
3) | Safety | Pool: | 15.4(4)l(4) | 21 |
Item: If a wading pool is within 50 ft. of a swimming pool, gates and doors shall be lockable. Except where lifeguard supervision is provided, gates and doors shall be self-closing and self-latching. | ||||
Comment: Wading pool is open while swimming pool is open. Lifeguards are available. Must have lifeguard posted at wading pool due to no self locking/self latching gates and fencing which would not allow other methods of access control. | ||||
4) | Safety | Pool: | 15.4(6)k | 25 |
Spa: | 15.51(5)i | 18 | ||
Item: Copies of MSDS sheets shall be available for employee review. Each member of staff shall review MSDS annually. | ||||
Comment: Not able to verify if SDS sheets are being annually reviewed. | ||||
Name | Date | ||
---|---|---|---|
Inspector: | Inspection: | ||
Report Received By: | Received: | ||
Reviewed By: | Reviewed: |
These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).