Swimming Pool / Spa
Inspection Report


Linn County Public Health
1020 - 6th Street SE
Cedar Rapids, IA 52401
Phone: (319) 892-6000 Fax: (319) 892-6099
E-mail: health@linncountyiowa.gov
  Facility Name: Bowman Woods Swim & Racquet Club
Address: 6600 Brentwood Dr NE
Cedar Rapids, IA  52402
Person Contacted: Reid Snell
Title: CPO
Registration No: SP57-003-102 \ SP57-003-100 \ SP57-003-101
Type: Routine

Water Quality Information
Name: Outdoor Waterslide-1st into pool Out. Pool >= 1500 Out. Wading Pool2
Registration No: SP57-003-102 SP57-003-100 SP57-003-101
Area (Sq. ft.): 3000 314
Volume (Gallons): 94000 2350
Filter Type:
Filter Rate:
Turnover Rate:
Chlorine (Free): 5.2 5.4 3.6
ORP: 685 685 685
Pool: 1-8ppm, ORP 700-880 mV
If less than 0.6ppm or greater than 8.0ppm = closure
Spa: 2-8 ppm ORP 700-880 mV
If less than 1.0ppm or greater than 8.0ppm = closure
Chlorine (Total):
Chlorine (Combined): 0 0 0
Bromine:
Pool: 2-18ppm Spa: 4-18ppm
Cyanuric Acid: <30 <30 <30
Must be less than 80 ppm
pH: 7.6 7.6 7.6
Pool and Spa: 7.2ppm-7.8ppm
If less than 6.8 or greater than 8.2 = closure
Total Alkalinity: 100 100 100
Calcium Hardness:

 

Water Quality Information (continued)
Name: Outdoor Waterslide-1st into pool Out. Pool >= 1500 Out. Wading Pool2
Registration No: SP57-003-102 SP57-003-100 SP57-003-101
Temperature (F):
Spa must not exceed 104°
Type of Disinfectant:
Disinfection make and model:
Drain Cover make and model:
Drain Cover exp. date:
CPO:
CPO exp. date:

Smoke Free Air Act
1. Facility in compliance with smoking ban?
( If no, complete complaint form )

Notes: FACILITY IS APPROVED TO RE-OPEN.
Recheck inspection completed to re-open pool. Items from previous inspection that have been corrected have been removed from report. All remaining items must still be corrected.

# Section Reference Ref. Page
1) Management/Personnel Pool: 15.4(6)l 25
Spa: 15.51(5)j 18
  Item: A written emergency plan shall be provided and reviewed annually
  Comment: Emergency plan is not reviewed annually.
   
2) Management/Personnel Pool: 15.4(6)f 24
Spa: 15.51(5)e 17
  Item: CPO must keep previous 12 months of Operational Records
  Comment: Previous 12 months of operational records were not able to be located.
   
3) Management/Personnel Pool: 15.4(6)f 24
Spa: 15.51(5)e 17
  Item: Records shall include results of chemical tests, results of microbial analyses, reports of complaints/injuries/illnesses, daily water temp. (spa), dates of draining/cleaning, and dates of review of MSDS
  Comment: Records did not include results of microbial analyses, dates of draining/cleaning, and dates of review of MSDS.
   
4) Management/Personnel Pool: 15.4(6)f(4) 24
Spa: 15.51(5)e(5) 17
  Item: Dates and quantities of chemical additions (superchlorination) must be included in Operational Records
  Comment: Dates and quantities of chemical additions is not included in operational records.
   
5) Management/Personnel Pool: 15.4(6)f(6) 24
Spa: 15:51(5)e(8) 17
  Item: Monthly ground fault circuit interrupter (GFCI) shall be included in Operational Records
  Comment: Monthly ground fault circuit interrupter testing is not included in operational records.
   
6) Management/Personnel Pool: 15.4(6)f(5) 24
Spa: 15.51(5)e(6) 17
  Item: Dates when filters are backwashed, cleaned, or changed included in Operational Records
  Comment: Dates when filters are backwashed, cleaned, or changed is not included in operational records.
   
7) Management/Personnel Pool: 15.4(2)e 10 and 11
Spa: 15.51(2)e 11 and 12
  Item: Not tested/recorded as often as necessary in Operation Records
  Comment: Testing not being recorded/completed as often as necessary.
   
8) Management/Personnel Pool: 15.4(6)b 23
  Item: "Pool Rules" signage incorrectly posted. Rules sign shall include No diving in shallow end, No horseplay, and No running on deck. Post conspicuously at a minimum of 2 locations within the swimming pool enclosure.
  Comment: "Pool Rules" signage not posted conspicuously in at least 2 locations.
   
9) Management/Personnel Pool: 15.4(6)e 24
  Item: "Water Slide Rules" signage incorrectly posted
  Comment: "Water Slide Rules" signage incorrectly posted.
   
10) Marking Pool: 15.4(4)i(2) 19
Spa: 15.51(4)g 15
  Item: Pool and Spa walls and floor shall be smooth and easily cleanable
  Comment: Missing significant amount of tiling around interior edge of pool.
   
11) Safety Pool: 15.4(4)b(2) 13
  Item: Pool ladders, ramps, handrails, and grab rails shall be securely anchored.
  Comment: Pool ladders are loose.
   
12) Safety Pool: 15.4(4)d(5) 16
  Item: Each water slide shall have a minimum of two attendants, one stationed at the top of the slide and one at the bottom of the slide.
  Comment: Water slide does not currently have any attendants and no alternate program has been approved for use.
   
  Name   Date
Inspector: Inspection:
     
Report Received By: Received:
Reviewed By: Reviewed:

These items must be corrected as soon as possible in order to comply with the Iowa Department of Public Health Swimming Pool and Spa Rules. A letter regarding the actions which will be taken in order to correct all deficiencies must be submitted within 30 days to this office. If for any reason you take issue with any of the items cited regarding swimming pool rules, a variance can be requested by following the instructions in the Iowa Department of Public Health Swimming Pools manual, amended July 8th, 2009, page 57, section 641-15.7 (135I). Variance requests regarding spa rules must be made in compliance with the instructions in the Iowa Department of Public Health Spa manual, revised July 8th, 2009, page 32, section 641-15.7 (135I).